OMIQ can import gating trees you have already built in other software so you do not have to recreate them by hand. Gates are imported with the Import Gates task and then applied in a downstream Gating task.
For common causes of import errors, see the Troubleshooting section of this article.
Currently, OMIQ Supports import of the following:
- FlowJo workspace (.wsp / .wspt) files from FlowJo v10
- Gating-ML files exported from Cytobank.
1. Import Gates from a FlowJo Workspace or Cytobank Gating-ML File
1.1 Add an Import Gates Task
Click Add new child task
Then select Import Gates from the task selector. You will find it under the Import / Export group.
1.2 Upload Your File and Run the Task
In Import Gates Settings, click the + button to upload your FlowJo .wsp/ .wspt file or Cytobank Gating-ML file.
Then click Run Import Gates.
1.3 Review the Imported Gating Trees
Import Gates identifies each unique gating tree group in your file.
If your FlowJo workspace has samples grouped as Control and Treated, Import Gates returns one .omiqgt file for each group. If a group contains more than one distinct gating tree, each tree is detected and returned as well.
2. Apply the Imported Gates in a Gating Task
2.1 Add a Gating Task Below Import Gates
Click Add new child task on the Import Gates task and select Gating. The imported gating tree is loaded into the new Gating task automatically.
2.2 Choose a Specific Gating Tree to Import
If your file contained more than one gating tree, or you want to apply a different tree, open any Gating task downstream of the Import Gates task and click Import Gates in the toolbar. Select the gating tree you want to apply to this Gating task.
Troubleshooting
Supported Files
- FlowJo .wsp and .wspt files from FlowJo v10. FlowJo v11 workspaces are not currently supported.
- Gating-ML files exported from Cytobank. Gating-ML files from other software are not supported. Although Gating-ML is intended as a shared standard, each software package writes it differently, and only the Cytobank version has been verified to work with Import Gates.
- Workspace files must be written by FlowJo. The Import Gates task was designed for .wsp / .wspt files created in FlowJo. Files generated by other tools, such as Python packages, can differ in structure and are not expected to be compatible.
Common Causes of Import Errors
If Import Gates returns an error, check your source file for the following:
- A Boolean gate whose parent is another Boolean gate. For example, a NOT gate that uses another NOT gate as its parent.
- A Boolean gate that references a source gate under a different parent. For example, a NOT T cells gate placed as a child of the B cells gate while still referencing the T cells gate elsewhere in the tree. OMIQ requires a Boolean gate and the gates it references to share the same parent.
- File names that do not match between OMIQ and the .wsp file. For example, a file named Sample 1 in OMIQ but Tube 1 in the FlowJo workspace. Rename the files so the names match exactly.
- Feature (parameter) names that do not match. For example, the .wsp file uses an underscore (_) as a separator while the OMIQ feature name uses a slash (/). Feature names must match exactly for gates to map onto the correct parameters.
If you have checked the items above and the import still fails, you can contact OMIQ support to investigate. We suggest sending your .wsp or Gating-ML file, a link to your shared workflow and a brief description of the error and we will take a look.